You are viewing from

About us

Start Buying

Start Selling

Create an Advert

Food Processing

Food Processing

Bakery Equipment

Beverage Processing

Catering Equipment

Cleaning & Sanitation

Cooking & Thermal Processing Equipment

Dairy Equipment

Depositing & Extruding Equipment

Food Handling & Storage

Inspection & Quality Control

Meat & Poultry Processing

Packaging Equipment

Preparation Equipment

Refrigeration & Freezing Equipment

Seafood Equipment

Site Production Infrastructure

Labs, Biotech & Pharma

Labs, Biotech & Pharma

Analytical Instruments & Detection Systems

Bioprocessing & Pharmaceutical Manufacturing

Clinical & Diagnostic Equipment

Cold Storage & Cryogenic Systems

Imaging, Microscopy & Histology

Lab Automation, Robotics & Workstations

Lab Consumables, Accessories & Support Equipment

Laboratory Packaging Equipment

Liquid Handling, Pumps & Fluid Control

Mixing, Agitation & Shaking

Molecular Biology & Genomics

Safety, Containment & Controlled Environments

Sample Preparation, Separation & Processing

Sterilization, Decontamination & Cleaning

Thermal Processing & Environmental Control

Utilities, Power & Facility Systems

Weighing, Measurement & Calibration

Heavy Equipment

Agriculture

Sign in
Home /
/
/

Sign up for new content updates

Get monthly insights on top brands, regions, equipment types and our latest inventory

We don't share your data. Check out our privacy policy.

New Equipment ListingsUsed Equipment ListingsFAQsContactBlog
About UsTerms & ConditionsPrivacy PolicyCookie Policy
LinkedInFacebookTwitter
New Equipment ListingsUsed Equipment ListingsFAQsContactBlog
About UsTerms & ConditionsPrivacy PolicyCookie Policy
LinkedInFacebookTwitter
trusted
© 2026 Machinery Masters - All rights reserved
GIR250 Gas Analyser by Hitech Instruments is a used chemical & biochemical analyzers listing available on Machinery Masters. Browse specifications, request seller details, and find similar equipment on Machinery Masters.
    Home
    /
    /
    Preview image 1
    Preview image 2
    Preview image 3
    Preview image 4
    Preview image 5
    Preview image 6
    Main image

    used Equipment

    Available

    Verified seller

    Hitech Instruments - GIR250 Gas Analyser

    Copied to clipboard!
    Price: Contact seller for price

    This listing is for the Hitech Instruments GIR250 Gas Analyser

    The unit is in full working condition and is ready for immediate use


    The GIR250 is a bench‑top / transportable analyser designed to measure oxygen (O₂) and carbon dioxide (CO₂) simultaneously in gas samples.

    It is made by Hitech Instruments (now part of the MTL / Eaton group).

    Its design emphasizes ease of use, reliability, and low maintenance cost.


    Other supporting features:

    The instrument can be programmed with pass/fail criteria for each gas (alarms).

    It provides analog outputs, typically 4–20 mA, for external logging or control systems.

    Calibration is designed to be simple (via the front panel keypad) to reduce training burden.

    The O₂ galvanic cell is user-replaceable (i.e. maintenance can be performed in the field).

    Mechanical, Electrical & Operational Details

    The GIR250 is housed in a rugged, transportable case (lab-style) so it can be used as a benchtop or mobile analyser.

    Sample inlet and outlet connections use 0.25″ (~6 mm) tubing.


    The sample system should avoid condensation and contaminants; non‑condensing sample environment is required.


    Operating ambient temperature: –5 to +40 °C (for non‑condensing conditions)

    Power / interface: standard for bench‑top analysers (the catalogue doesn’t always detail it, but likely mains or DC supply, suitable for lab use)

    Typical Applications & Suitability

    Because it can measure both O₂ and CO₂ in a single unit, the GIR250 is used in applications such as:

    Respiration / breathing gas analysis / Douglas bag analysis (i.e. in physiological or experimental gas mixture measurement)

    Fermentation / bioprocess monitoring (where O₂ and CO₂ both matter)

    Gas mixture / inertisation / process gas quality (checking gas purity, calibrating mixtures)

    It is not primarily intended for measuring very low trace levels (ppm-level) of O₂ or CO₂ unless its ranges are suitably adapted or specified. The design is more for percent-range analysis

    United KingdomCambridgeshire, United Kingdom

    5,791 km away

    Model Number

    GIR250

    Stock Number

    240850/7B

    Machinery Masters View

    Typical context for this category of equipment. Always confirm specifics with the seller.

    Applications & Use Cases

    • Monitoring gas composition in controlled atmosphere storage for food preservation.
    • Analysing gas mixtures in fermentation processes within biotechnology.
    • Checking gas purity in medical and pharmaceutical gas supply systems.
    • Environmental monitoring for O₂ and CO₂ levels in industrial settings.
    • Quality control in packaging operations where gas flushing is used.

    Typical Specifications

    Typical gas measurement range
    Units of this type commonly measure O₂ from 0-100% and CO₂ from 0-100%, or specific sub-ranges depending on the sensor configuration.
    Measurement principle
    Typically uses a galvanic cell for oxygen and an infrared sensor for carbon dioxide.
    Sample connections
    Commonly uses 0.25" (approximately 6 mm) tubing for sample inlet and outlet.
    Power supply
    For this class of benchtop analyser, a standard mains power supply (e.g., 230V AC, 50Hz for UK operation) or a low-voltage DC supply is typical.
    Output signals
    Units commonly provide analogue outputs, such as 4-20 mA, for integration with external control or data logging systems.
    Operating temperature range
    Typically designed for operation in ambient temperatures ranging from -5 to +40 °C, assuming non-condensing conditions.
    Maintenance
    Features like user-replaceable oxygen sensors are common, reducing the need for specialist service calls.

    Frequently Asked Questions

    • This model is designed to measure oxygen (O₂) and carbon dioxide (CO₂) simultaneously. Buyers should confirm specific measurement ranges with the seller.

    Machinery Masters Intelligence. General guidance for this category of equipment only, not a substitute for the seller's exact specifications. Always confirm details with the seller.

    Related Products

    Fragment Analyser Capillary Electrophoresis System
    usedAvailable

    Product category: Chemical & Biochemical Analyzers

    AATI - Fragment Analyser Capillary Electrophoresis System

    311 Chemistry Analyser
    usedAvailable

    Product category: Chemical & Biochemical Analyzers

    Astoria Pacific - 311 Chemistry Analyser

    Agilent 2100 Bioanalyser
    usedAvailable

    Product category: Chemical & Biochemical Analyzers

    Agilent Technologies - Agilent 2100 Bioanalyser