Steris-Finn Aqua - WFI Generation And Storage System
Copied to clipboard!
Price: Contact seller for price
System Overview
A complete, cGMP-compliant Water for Injection (WFI) generation and storage system. Produces high-purity, endotoxin-free water for pharmaceutical and biotech applications via multiple-effect distillation.
This item can be crated and shipped internationally. Please contact us for a quotation
Main Components
Finn-Aqua 200-S3 Distillation Unit – three-effect evaporator/condensers with falling-film design, pyrogen separation, and continuous blowdown.
600 L WFI Storage Tank – 316L stainless steel, atmospheric vent filter, level and temperature sensors.
600 L Jacketed Holding Tank – 316L stainless steel, insulated, steam/hot water jacket for temperature control.
WFI Distribution Pump – sanitary centrifugal pump for loop circulation.
Utility Connections – plant steam (3–8 bar), cooling water, feed water, condensate return, and instrument air.
Instrumentation – pressure, temperature, conductivity, and level transmitters with safety and relief valves.
Control Panel – PLC-based automatic operation, alarm handling, data logging, and local/remote control.
Key Features
Multi-effect distillation for high purity and energy efficiency.
Degassing and three-stage separation for endotoxin removal.
Fully stainless, drainable, and sanitary construction.
Compact, skid-mounted design with integrated utilities.
Designed for validation and GMP compliance (USP/EP WFI quality).